Frequency converter 5.5 kW BM2200-5R5G

SKU: 00099397

412.37 EUR

apple pay photo google pay photo
Type of equipment

MIXXMANN S6,   MIXXMANN S8,   MIXXMANN S5

Brand

MIXXMANN

View

Frequency converter

Power

5.5 kW

High-voltage

230V

Frequency Converter

·         Control Mode:

Sensorless Vector Control of Flow (SFVC). Voltage/Frequency Control (V/F)

·         Maximum Frequency:

Vector Control: 0-320 Hz
V/F Control: 0-3200 Hz

·         Operational Frequency:

1 kHz - 16 kHz. The operational frequency can be automatically adjusted depending on the load function.

·         Input Frequency Resolution:

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.025%

·         Starting Torque:

Type G: 0.5 Hz/150% (SFVC);
Type P: 0.5 Hz/100%

·         Speed Range:

1:100 (SFVC)

·         Speed Stability Accuracy:

±0.5% (SFVC)

·         Overload Capacity:

Type G: 60 s for 150% rated current, 3 s for 180% rated current.
Type P: 60 s for 120% rated current, 3 s for 150% rated current.

·         Torque Boost:

Fixed boost/Tuneable boost 0.1%–30.0%

·         V/F Curve:

Straight V/F curve
Multi-point V/F curve

V/F curve power N (1.2 power, 1.4 power, 1.6 power, 1.8 power, rectangular)

·         V/F Separation:

Two types: full separation; half-separation

·         Ramp/Acceleration Mode:

Straight ramp

S-curve ramp/acceleration

Four groups of acceleration/deceleration time ranging from 0.0–6500.0 s

·         DC Braking:

DC braking frequency: from 0.00 Hz to maximum frequency. Braking time: 0.0–100.0 s

Braking current value: 0.0%–100.0%

·         JOG Control:

JOG frequency range: 0.00–50.00 Hz

JOG acceleration/deceleration time: 0.0–6500.0 s

·         Multiple Built-in Pre-set Speeds:

Realizes up to 16 speeds using a simple PLC function or through input terminal states (X)

·         Built-in PID Controller:

Easily implements a closed-loop control system, driven by the process.

·         Automatic Voltage Regulation (AVR):
Can automatically maintain constant output voltage as the supply voltage changes.

·         Overvoltage/Overcurrent Stop Control:

Current and voltage are automatically limited during operation to avoid frequent trips due to
overvoltage/overcurrent.

·         Torque Limiting and Control:
It can automatically limit torque and prevent frequent trips due to current overload during operation.

·         Instant Stop Does Not Halt:

Feedback energy from the load compensates for voltage drop so that the AC drive can continue to operate for a short time.

·         Fast Current Limiting:

Helps avoid frequent overcurrent overloads in the AC drive.

·         High Performance:

Control of the asynchronous motor is implemented using high-performance current vector control technology.

·         Time Control:

Time range: 0.0–6500.0 minutes

·         Communication Methods: RS485

·         Control Work Channel:

Provided by panel, control terminals, serial communication port, can switch in many ways

·         Frequency Source:

10 types of frequency sources provided: Digital analog voltage signal, analog current, pulse, serial port. Can switch in many ways

·         Auxiliary Frequency Source:

10 types of frequency sources provided: Digital analog voltage signal, analog current, pulse, serial port. Can switch in many ways.

·         Input Terminals:

6 digital input terminals, one of which supports high-speed pulse input up to 100 kHz. (optional) 2 analog input terminals, one of which supports only voltage input 0-10 V, and the other supports voltage input 0-10 V and current input 4-20 mA.

·         Output Terminals:

1 digital output terminal, 1 relay output terminal, 1 analog output terminal.

Terminal: supports current output 0–20 mA or voltage 0–10 V output

·         Control Panel Operation:

·         LED Display:

Displays parameters.

·         Key Lock and Function Selection:

Keys can be partially or fully locked, and the function range of certain keys can be defined to prevent incorrect operation.

·         Protection Mode:

Motor short-circuit detection during startup, output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheating protection, and overload protection.

·         Installation Location:

Indoors, avoid direct sunlight, dust, aggressive gases, flammable gases, oil mist, steam, droplets, or salts.

·         Altitude:

Less than 1000 m (lower grades for use above 1000 m)

·         Ambient Temperature:

-10℃ ~40℃ (lower grades for use in the range of 40℃ to 50℃)

·         Humidity:

Less than 95% relative humidity, no condensation

·         Vibration:

Less than 5.9 m/s² (0.6 g)

·           Storage Temperature:

-20℃ ~60℃

Pre-order: ""

Specify the price: ""

Search

Shopping Cart

Your shopping cart is empty!

Login


New customer? Create your account

Lost password? Recover password

Recover password


Remembered your password? Back to login

Register


Already have an account? Login here

EUR photo EUR photo en | EUR
Language: en
Currency: EUR