Frequency converter 11kW BM2200-11G

SKU: 00099399

512.73 EUR

apple pay photo google pay photo
Brand

No brand

View

Frequency converter

Power

11 kW

High-voltage

230V

Frequency Converter

·         Control Mode:

Sensorless Vector Control of Flux (SFVC). Voltage/Frequency Control (V/F)

·         Maximum Frequency:

Vector Control: 0-320 Hz
V/F Control: 0-3200 Hz

·         Operating Frequency:

1 kHz - 16 kHz. The operating frequency can be automatically adjusted according to the load function.

·         Input Frequency Resolution:

Digital Setting: 0.01 Hz

Analog Setting: Maximum Frequency x 0.025%

·         Starting Torque:

Type G: 0.5 Hz/150% (SFVC);
Type P: 0.5 Hz/100%

·         Speed Range:

1:100 (SFVC)

·         Speed Stability Accuracy:

±0.5% (SFVC)

·         Overload Capacity:

Type G: 60 s for 150% rated current, 3 s for 180% rated current.
Type P: 60 s for 120% rated current, 3 s for 150% rated current

·         Torque Boost:

Fixed boost/Tunable boost 0.1%–30.0%

·         V/F Curve:

Linear V/F Curve
Multi-Point V/F Curve

Power V/F Curve N (1.2 power, 1.4 power, 1.6 power, 1.8 power, rectangular)

·         V/F Separation:

Two types: full separation; half break

·         Ramp/Acceleration Mode:

Linear Ramp

S-curve Ramp/Acceleration

Four groups of acceleration/deceleration times ranging from 0.0–6500.0 s

·         DC Braking:

DC braking frequency: from 0.00 Hz to maximum frequency. Braking time: 0.0-100.0 s

Braking current value: 0.0%–100.0%

·         JOG Control:

JOG Frequency Range: 0.00–50.00 Hz

JOG Acceleration/Deceleration Time: 0.0–6500.0 s

·         Multiple Built-in Pre-set Speeds:

Realizes up to 16 speeds using simple PLC function or through input terminal states (X)

·         Built-in PID Controller:

Easily implements closed-loop control system, process controlled.

·         Automatic Voltage Regulation (AVR):
Can automatically maintain a constant output voltage when the power supply voltage changes.

·         Overvoltage/Overcurrent Stop Control:

Current and voltage are automatically limited during operation to avoid frequent tripping due to
overvoltage/overcurrent.

·         Torque Limiting and Control:
It can automatically limit torque and prevent frequent tripping due to overcurrent during operation.

·         Instant Stop Does Not Halt:

Load feedback energy compensates for voltage drop, allowing the AC drive to continue operating for a short time.

·         Fast Current Limiting:

This helps to avoid frequent overcurrent overloads of the AC drive.

·         High Performance:

Asynchronous motor control is implemented using high-performance current vector control technology.

·         Time Control:

Time range: 0.0–6500.0 minutes

·         Communication Methods: RS485

·         Operation Control Channel:

Issued by the panel, control terminals, Serial communication port, can switch by many methods

·         Frequency Source:

10 types of frequency sources issued: Digital analog voltage signal, analog current, pulse, serial port. Can switch by many methods

·         Auxiliary Frequency Source:

10 types of frequency sources issued: Digital analog voltage signal, analog current, pulse, serial port. Can switch by many methods.

·         Input Terminals:

6 digital input terminals, one of which supports high-speed pulse input up to 100 kHz. (optional) 2 analog input terminals, one of which supports only voltage input of 0-10 V, and the other supports both voltage input of 0-10 V and current input of 4-20 mA.

·         Output Terminals:

1 digital output terminal, 1 relay output terminal, 1 analog output terminal.

Terminal: supports current output 0–20 mA or voltage output 0–10 V

·         Control Panel Operation:

·         LED Display:

Displays parameters.

·         Key Locking and Function Selection:

Keys can be partially or fully locked and the function range of some keys can be defined to prevent incorrect operation.

·         Protection Mode:

Motor short circuit detection during power on, output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheating protection, and overload protection.

·         Installation Location:

Indoors, avoid direct sunlight, dust, aggressive gas, flammable gas, oil mist, vapor, droplets, or salts.

·         Altitude:

Less than 1000 m (lower degrees for use above 1000 m)

·         Ambient Temperature:

-10℃ to 40℃ (lower degrees for use in the range of 40℃ to 50℃)

·         Humidity:

Less than 95% relative humidity, no condensation

·         Vibration:

Less than 5.9 m/s² (0.6 g)

·         Storage Temperature:

-20℃ to 60℃

Pre-order: ""

Specify the price: ""

Search

Shopping Cart

Your shopping cart is empty!

Login


New customer? Create your account

Lost password? Recover password

Recover password


Remembered your password? Back to login

Register


Already have an account? Login here

EUR photo EUR photo en | EUR
Language: en
Currency: EUR