Frequency converter

Power

7.5 kW

High-voltage

230V

Frequency Converter

·         Control Mode:

Sensorless Vector Control of Flux (SFVC). Voltage/Frequency Control (V/F)

·         Maximum Frequency:

Vector Control: 0-320 Hz
V/F Control: 0-3200 Hz

·         Operating Frequency:

1 kHz - 16 kHz. The operating frequency can be automatically adjusted according to the load function.

·         Input Frequency Resolution:

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.025%

·         Starting Torque:

Type G: 0.5 Hz/150% (SFVC);
Type P: 0.5 Hz/100%

·         Speed Range:

1:100 (SFVC)

·         Speed Stability Accuracy:

±0.5% (SFVC)

·         Overload Capacity:

Type G: 60 s for 150% rated current, 3 s for 180% rated current.
Type P: 60 s for 120% rated current, 3 s for 150% rated current

·         Torque Boost:

Fixed boost/Tunable boost 0.1%–30.0%

·         V/F Curve:

Linear V/F curve
Multi-point V/F curve

Power V/F curve N (1.2 power, 1.4 power, 1.6 power, 1.8 power, rectangular)

·         V/F Separation:

Two types: full separation; half separation

·         Acceleration/Deceleration Mode:

Linear ramp

S-shaped ramp/acceleration

Four groups of acceleration/deceleration times ranging from 0.0–6500.0 s

·         DC Braking:

Braking frequency: from 0.00 Hz to maximum frequency. Braking time: 0.0-100.0 s

Braking current values: 0.0%–100.0%

·         JOG Control:

JOG frequency range: 0.00–50.00 Hz

JOG acceleration/deceleration time: 0.0–6500.0 s

·         Multiple Built-in Pre-set Speeds:

Supports up to 16 speeds via simple PLC function or through input terminal states (X)

·         Built-in PID Controller:

Easily implements a closed-loop control system, process controlled.

·         Automatic Voltage Regulation (AVR):
Can automatically maintain constant output voltage with changes in the network voltage.

·         Overvoltage/Overcurrent Fault Stop Control:

Current and voltage are automatically limited during operation to avoid frequent tripping due to
overvoltage/overcurrent.

·         Torque Limiting and Control:
It can automatically limit the torque and prevent frequent tripping due to current overload during operation.

·         Instant Stop Doesn't Stop:

Feedback energy from the load compensates for the voltage drop, allowing the AC drive to continue to operate for a short time.

·         Fast Current Limiting:

This helps avoid frequent current overloads in the AC drive.

·         High Performance:

Control of the asynchronous motor is achieved using high-performance vector control technology.

·         Time Control:

Time range: 0.0–6500.0 minutes

·         Communication Methods: RS485

·         Control Work Channel:

Issued by the panel, control terminals, serial communication port, can be switched in many ways

·         Frequency Source:

10 types of frequency sources available: Digital analog voltage signal, analog current, pulse, serial port. Can be switched in many ways

·         Auxiliary Frequency Source:

10 types of frequency sources available: Digital analog voltage signal, analog current, pulse, serial port. Can be switched in many ways.

·         Input Terminals:

6 digital input terminals, one of which supports high-speed pulse input up to 100 kHz (optional). 2 analog input terminals, one supporting only voltage input 0-10 V, and the other supporting voltage input 0-10 V and current input 4-20 mA.

·         Output Terminals:

1 digital output terminal, 1 relay output terminal, 1 analog output terminal.

Terminal: supports current output 0–20 mA or voltage output 0–10 V

·         Control Using Control Panel:

·         LED Display:

Displays parameters.

·         Key Lock and Function Selection:

Keys can be partially or fully locked, and the range of functions for certain keys can be defined to prevent incorrect operation.

·         Protection Mode:

Detection of motor short circuit during startup, output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheating protection, and overload protection.

·         Installation Location:

Indoors, avoiding direct sunlight, dust, corrosive gases, flammable gases, oil mist, steam, drops, or salts.

·         Height Above Sea Level:

Less than 1000 m (lower ratings for use above 1000 m)

·         Ambient Temperature:

-10℃ ~40℃ (lower ratings for use in the range of 40℃ to 50℃)

·         Humidity:

Less than 95% relative humidity, no condensation

·         Vibration:

Less than 5.9 m/s2 (0.6 g)

·         Storage Temperature:

-20℃ ~60℃

Related Products

Pre-order: ""

Specify the price: ""

Search

Shopping Cart

Your shopping cart is empty!

Login


New customer? Create your account

Lost password? Recover password

Recover password


Remembered your password? Back to login

Register


Already have an account? Login here

EUR photo EUR photo en | EUR
Language: en
Currency: EUR