Manometer 0-100 bar glycerin-filled pressure gauge PFT l (bottom connection) is a mechanical measuring instrument for monitoring the pressure of construction mixtures in the pumping systems of PFT plastering equipment. It is designed for installation in the pressure pipeline via a suitable threaded connection and allows for visual monitoring of pressure during the transportation of plastering, adhesive, and other compatible construction mixtures. The measurement range from 0 to 100 bar enables the tracking of pressure changes during the operation of the screw pump, allowing for timely detection of deviations from normal material delivery conditions.
A distinctive feature of the manometer is its glycerin filling, which provides damping of needle oscillations caused by pressure pulsations and equipment vibrations. This results in more stable readings that are easier to read during pump operation. Glycerin also reduces mechanical loads on the moving parts of the measuring mechanism, which is especially important in conditions of intensive use of plaster stations.
The device features a round housing with a nominal diameter dial of 63 mm. Pressure markings in bar and PSI are displayed on the scale, allowing readings in various units of measurement. The primary range is 0-100 bar, while an additional scale reflects corresponding values up to 1450 PSI. The mechanical needle indicator allows for direct pressure monitoring without the need for electrical power connection.
The dial indicates standard EN 837-1 and an accuracy class of 2.5. These designations characterize the execution of the measuring device and the permissible error of its readings. The contrasting scale markings enable monitoring of pressure changes during equipment operation, and the needle mechanism displays the current value at the point where the manometer connects to the pressure system.
The manometer is equipped with a 1/4 inch bottom threaded connection. The connection fitting is located at the bottom of the housing, allowing for vertical installation on the appropriate measuring unit or solution pipeline adapter. This design differs from manometers with rear connections and should be considered when selecting a spare part for specific equipment.
The external part of the manometer features a black protective cover with pronounced ribbing. It surrounds the measuring device's housing, providing additional mechanical protection against accidental impacts during operation, transportation, and maintenance of the equipment. The ribbed design helps to absorb mechanical impacts, while the front remains open for easy reading of the dial's indications.
During the operation of a plaster station, the screw pump generates the necessary pressure to transport the prepared mixture through the pressure hose to the application site. The pressure value depends on the properties of the mixture, the resistance of the solution pipeline, the length of the hoses, and the operating mode of the pump mechanism. The manometer installed in the appropriate measuring unit allows for monitoring these changes and assessing the stability of material delivery.
A sudden increase in pressure may indicate an increase in resistance to the flow of the mixture, a change in its consistency, or the occurrence of a blockage in the pressure pipeline. A decrease in readings may be related to insufficient material supply, wear of the screw pair, or other changes in equipment operation. The manometer helps to detect such deviations; however, it does not regulate pressure on its own and does not replace protective devices in the pump system.
The glycerin filling is particularly beneficial for equipment that experiences pressure fluctuations and constant vibrations. The damping effect on the needle makes it easier to observe readings, reduces sharp oscillations, and contributes to a more stable operation of the measuring mechanism. This allows the device to be used for pressure monitoring in construction sites where pump equipment operates with various consistency materials.
Before installation, the condition of the lower threaded fitting, sealing elements, and the corresponding connection unit must be checked. Installation should be performed on stopped equipment after complete pressure release in the system. During tightening, the designated edges of the fitting must be used, avoiding excessive force transfer to the manometer's housing. After installation, it is important to check the tightness of the connection and the accuracy of the readings.
The need to replace the manometer may arise in case of mechanical damage to the housing, loss of hermeticity, malfunction of the needle mechanism, or appearance of incorrect readings. If the needle does not return to the zero position after complete pressure release, the device requires inspection. Damage to the protective glass or leakage of the glycerin liquid also warrants an inspection and assessment of the manometer's suitability for further use.
The glycerin manometer PFT with a bottom threaded connection is designed for pressure monitoring in compatible pump systems for plaster equipment. Compact housing, dual scale measurements, damping filling, and a protective cover provide convenience during construction work and maintenance of solution pipelines.
Type of product: solution pressure manometer.
Brand: PFT.
Type of instrument: mechanical, needle.
Purpose: measurement and monitoring of construction mixture pressure.
Measurement range: 0-100 bar.
Additional scale: PSI, up to 1450.
Nominal diameter of the dial: 63 mm.
Type of filling: glycerin.
Accuracy class: 2.5, as marked on the dial.
Standard of the measuring instrument: EN 837-1, as per marking.
Connection size: 1/4 inch.
Connection location: bottom.
Type of connection: threaded.
Design: round housing with needle measuring mechanism, glycerin filling, and bottom fitting.
Housing protection: black ribbed protective cover.
Function of glycerin filling: damping needle oscillations and reducing the impact of vibrations on the measuring mechanism.
Compatible equipment: plaster stations and pump systems from PFT with the appropriate connection for the manometer.
Installation location: pressure pipeline monitoring unit.
Installation method: threaded connection via bottom fitting.
Features: glycerin filling, dual measurement scale, bottom threaded connection, protection from mechanical impacts.
Application: monitoring pressure of construction mixtures, repair, and maintenance of PFT pumping equipment.